d&b audiotechnik Z5354 Инструкции по монтажу - Страница 8

Просмотреть онлайн или скачать pdf Инструкции по монтажу для Адаптер d&b audiotechnik Z5354. d&b audiotechnik Z5354 10 страниц. E8/e12 flying adapter link

Securing pin o.k.
Change the securing pin
Condition of the securing pin
Z5354/Z5355, Mounting instructions
7.

Maintenance and care

Storing/Transport
Due to its surface treatment the components are temporarily protected
against moisture. However, ensure the components are in a dry state
while stored or during transport and use.
During transport ensure the components are not stressed or damaged
by mechanical forces.
Cleaning
Regularly clean and lubricate the components using an anti-corrosion
agent.
Inspections
To eliminate the potential risk of accident due to malfunctioning of the
components carry out a visual and functional inspection of the
components regularly.
If the components fail to operate correctly and/or safely the bracket
must be withdrawn from use immediately.
Flying adapter and link
In particular pay attention to obvious damage, deformation, cracks and
corrosion.
Securing pin (Rue ring cotter)
Visually inspect the securing pin for obvious damage and deformation.
Also carry out a functional test of the locking mechanism.
If it is no longer possible to fit and lock the securing pin, it must be
replaced (refer to the graphic opposite).
d&b order code: Q9083 (Securing pin RUE 22).
8.

Disposal

Please dispose of this product according to the respective national
regulations.
Ensure that damaged rigging components are disposed of in a way that
they can not be used again.
(1.3 EN)