D'Amore Engineering AMM-1 Руководство пользователя - Страница 13

Просмотреть онлайн или скачать pdf Руководство пользователя для Мультиметр D'Amore Engineering AMM-1. D'Amore Engineering AMM-1 16 страниц. Smd

D'Amore Engineering AMM-1 Руководство пользователя

Real Time Power Mode

In this mode the AMM-1 will show the True Power
compensated for both Power Factor and clipping of the
signal in a live mode.
How to measure True Power
1. Power on the AMM-1 by pressing the ON button
2. Unit will power up, display internal battery condition,
and then land on the DC Voltage Screen.
3. Press the MODE button five times (or hold down) to
get to the Real Time Power screen.
4. Shut off AC source (amplifier)
5. Disconnect one of the wires from the load of interest
(subwoofer)
6. Run the either the negative or positive speaker wire
through the hole on the center of the AMM-1, and
reconnect the wire to the load.
which one, but only use ONE of them)
7. Connect the voltage harness to the banana jacks
and then to the amplifier speaker outputs (+) and (-)
8. Power up AC current source (amplifier) and apply a
signal with a tone generator or tone CD.
9. The AMM-1 will display the True Power in Watts,
compensated for both clipping and Power Factor.
(Doesn't matter
13