Ambifuego KALIDO 73 Инструкции по установке, эксплуатации и обслуживанию - Страница 7

Просмотреть онлайн или скачать pdf Инструкции по установке, эксплуатации и обслуживанию для Крытый камин Ambifuego KALIDO 73. Ambifuego KALIDO 73 15 страниц. Convector gas fire

molex connector. Fix into place with the four screws previously removed.
10
Temporarily place the burner and mark the gas pipe for cutting. Trim the gas supply pipe
to the mark. The end of the supply tube should finish 10 mm above the base. Prior to
connecting the burner to the gas supply it is advisable to blow out the pipe to clear any
dirt that may be present and which could cause a blockage in the control valve or pilot.
11
Replace the connection from the flue temperature switch and tighten the thermocouple
nut (Caution; do not over tighten). Replace the burner/control assembly in position and
secure. Fix the switch box to the gas control valve with the M4 screw previously
removed. Replace the fascia panel and secure with four black headed self tapping
screws. Using the nut and olive provided, connect the 8mm supply pipe to the pressure
test point fitting.
12

Gas Soundness Check

Once the gas supply is connected, all joints must be checked for gas soundness . Note:
It is permissible to light the fire for short periods when the burner has not been filled with
the loose infill.

ELECTRICAL CONNECTION TO MAINS SUPPLY

1
It is recommended that the electrical connection to the mains supply is made via a fused
spur or an un-switched three-pin socket and plug. The supply MUST BE FITTED WITH A
3A FUSE.
2
The appliance is supplied with 2.5 metres of three-core mains cable pre- wired to the
circulation fan and its speed control switch. This should be routed to the power point as
inconspicuously as possible - i.e. chased into the plaster.

Filling the Burner.

Fill the burner tray level to the top using the ceramic fibre flakes provided making sure
that the burner ports between the flame guides down the centre are left completely clear.
Any flakes that are too large may be broken to fit.

Placing of the Refractory Logs.

Keep logs clear of the pilot flame to ensure good cross lighting.
Lay the logs a shown in the Figures.
7