amc VIBRO AV MONITOR 1002DX Kullanıcı Kılavuzu - Sayfa 15

Ölçüm Cihazları amc VIBRO AV MONITOR 1002DX için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. amc VIBRO AV MONITOR 1002DX 16 sayfaları. Condition monitoring system with relay outputs

ATTENTION! In some types of AVM 1002DX modules some of the above functions are not
active.

10. Technical parameters

PARAMETER
sensor type
measured values
types of estimates
power supply
power consumption
low-pass filter
high-pass filter
insulation
current output:
voltage output
delay
alarm level
warning level
relay outputs
operating temperature
operating relative humidity
protection class
dimensions
mounting
15
VALUE
DX: IEPE, 100 mV/g , 8 mA/20 V
DT: 10 mV/°C
DX: vibration velocity, acceleration
DT: temperature
RMS, 0-PEAK
24 VDC (18..36 VDC)
<4 W
DX: 1 and 10 kHz, 24 dB/oct., 4
DT: no LPF filter
DX: 3 and 10 Hz, 12 dB/oct., 2
DT: no HPF filter
1 kV DC (2 or 3 kV DC optionally)
2 or 3 wired 4..20 mA current loop
AC, 10V
max
pp
0 - 16s every 1s
0 – 99
0 – 99
24 V/100 mA, NO
o
-20..+60
C
<95% RH
IP20
23 x 100 x 120 (W x H x L)
35 mm DIN rail
th
order
nd
order
AV MONITOR 1002DX