Birchdale Cast Iron 0715 07/07/2015 16:35 Page 11
To remove the internal vermiculite baffle:
Firstly remove the front fuel retaining
bars.
Then slightly lift the baffle and ease one
of the side bricks forward by pulling the
front edge of the side brick into the
Ensure the serial number has been recorded on the front of this manual for any
future use
Ensure the door seals are in good condition and that the glass is secured correctly
in the door (do not over tighten the glass as this will prohibit its expansion and
could cause the glass to crack)
Ensure that all internal components are fitted correctly (these may have shifted in
transit)
Ensure that the appliance operates correctly during the first firing
Ensure the customer is aware that fumes may be given off during the first firings
as the paint cures
Advise the customer on the safe operation of the appliance
Leave the instruction manuals, operating tool and glove for the customer's use.
Record the flue draught reading of the appliance

Commissioning Check List

Please tick boxes when each procedure is completed
combustion chamber. Remove the
second side brick in the same manner,
the flue baffle can now be removed by
lowering the front edge and rotating the
baffle and removing through the front
door.