AMD DIrect FPB-19DPSSF11TPSI-N Kurulum ve Kullanım Talimatları Kılavuzu - Sayfa 4

Dış Mekan Şömine AMD DIrect FPB-19DPSSF11TPSI-N için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Talimatları Kılavuzu indirin. AMD DIrect FPB-19DPSSF11TPSI-N 20 sayfaları. Round flat disc fire pits with thermocouple piloted safety ignition (tpsi) & pro brass snowflake burner

MODELS
N = Natural
P = Propane
FPB-19DPSSF11TPSI-N
FPB-19DPSSF11TPSI-P
FPB-25DPSSF18TPSI-N
FPB-25DPSSF18TPSI-N
FPB-29DPSSF18TPSI-N
FPB-29DPSSF18TPSI-N
Table 1 Fire Pit Dimensions
*
Drop-In Pan
2 ½"
.875 TYP. (usable lip area)
Fig. 1 Burner pan specifications.
Pressure
Min. Inlet
3.5" WC (0.87 kPa)
Max. Inlet
10.5" WC (2.61kPa)
Normal Inlet 7.0" WC (1.74 kPa)
Table 2 Gas Pressures
Models:
Natural Gas
FPB-19DPSSF11TPSI-N
FPB-25DPSSF18TPSI-N
FPB-29DPSSF18TPSI-N
Table 3 Burner specifications.
Disclaimer: BTU listings are based on 7.0"WC for Natural Gas
and 11.0"WC for Liquid Propane (LP) at the burner orifice. Flex
line size and proper gas pipe sizing will also affect BTU's. As a
result your BTU's may vary slightly from Table 2 specifications.
Rd. Flat Pan Fire Pits with Brass Snowflake Burner with TPSI Ignition

SPECIFICATIONS

PAN
DIMENSIONS
(I.D.)
19" Diameter (I.D.)
(483mm)
25" Diameter (I.D.)
(635mm)
29" Diameter (I.D.)
(737mm)
O.D.
I.D.
8"
Ground Level (Earth)
NG
LP
8.0" WC (1.99kPa)
13.0" WC (3.23 kPa)
11.0" WC (2.73 kPa)
#
NG Injector
BTU
Jets
Size
Ratings
8
#61 (0.039)
50K
24
#61 (0.039)
145K
24
#61 (0.039)
145K
MAX.
BURNER
OPENING SIZE
SIZE
20" Diameter
11" Sq.
(508mm)
(279mm)
.
26" Diameter
18" Sq
(660mm)
(457mm)
27" Diameter
18" Sq.
(686mm)
(457mm)
*
Fig. 2 Clearance to Combustibles for models.
(Not to be used in an enclosed space)
Models:
Propane Gas
FPB-19DPSSF11TPSI-N
(14.65kW)
FPB-25DPSSF18TPSI-N
(42.95kW)
FPB-29DPSSF18TPSI-N
(42.95kW)
CAUTION:
No LPK conversion kits are available for brass burners.
You must order the correct burner.
GROUND
SIDE
COMBUSTIBLE
LEVEL
WALL
CEILING
8"
36"
(203mm)
(914mm)
(3048mm)
8"
36"
120"
(203mm)
(914mm)
(3048mm)
8"
36"
120"
(203mm)
(914mm)
(3048mm)
Combustible Ceiling
36"
Max
Overhang
C L
96/120"
36"
Combustible Floor
LP Injector
BTU
Size
Ratings
#72 (0.025)
42K
#72 (0.025)
124K
#72 (0.025)
124K
COMBUSTIBLE
FLOOR
96"
18"
(457mm)
18"
(457mm)
18"
(457mm)
18"
(12.30kW)
(36.34kW)
(36.34kW)
REV. A
Page 4