AME Intl. 13155 Kullanım Kılavuzu - Sayfa 4

Kaldırma Sistemleri AME Intl. 13155 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. AME Intl. 13155 5 sayfaları. 100 ton aluminum cylinder with locking collar

Always keep cylinder clean, use dust cap to protect coupler.
After finish work, Cylinder must be fully retracted, cleaned and stored in ventilation,
moist-proof, corrosion-proof place.
7. TROUBLE-SHOOTING
WARNING: AME International Cylinders should be repaired only by a qualified
operator or authorized AME International Service Center. Repair cylinders without
special tools and knowledge may result in personal injury. Please release pressure and
disconnect hose(s) before making repair.
Problem
1.Pump release valve open
2.Couplers not fully tightened
Cylinder
will
not
3.Oil level in pump reservoir is low
extend
or
fully
4.Pump or valve malfunctioning
extend
5.Overload for cylinder
6.Cylinder piston rod binding
1.Leaky connection
Cylinder can not
2.Cylinder seals leaking
maintain pressure
3.Release valve not fully closed
4.Pump or valve malfunctioning
1. Leaky connection
Cylinder
extends
2. Coupler not fully tightened
slower than normal
3. Pump malfunctioning
Cylinder extend in
1. Air in system
dithering
2. Cylinder piston rod binding
1. Leaky connection
Cylinder
leaks
2. Worn or damaged seals
hydraulic oil
3. Cylinder damage
AME INTERNATIONAL
Cause
4
Solution
1.Fully tighten pump release valve
2.Fully tighten couplers
3.Fill oil in pump
4.Repair or use another pump and valve
5.Change another cylinder with appropriate
capacity
6.Check for dirt or leaks, change the damage
parts
1.Clean and reseal thread, tighten connection
2. Replace worn seals. Clean inside cylinder and
use clean hydraulic oil
3. Fully tightening the release valve
4. Repair, or use another pump and valve
1.Clean and reseal thread, tighten connection
2. Fully tighten couplers
3. Repair or use another pump and valve
1. Bleeding air in the system
3. Check for dirt or leaks. Check for bent,
misaligned and worn parts
1.Clean and reseal thread, tighten connection
2.Replace worn seals, clean inside cylinder and
use clean hydraulic oil
3. Use new cylinder of contact with your nearest
Authorized AME International Hydraulic Service
Center.
www.ameintl.net