OPERATION
Operation
Other features
FOLLOW ME/TEMP SENSING feature(optional)
NOTE:This feature can be activated from the remote control ONLY. The remote control
serves as a remote thermostat allowing for the precise temperature control at its location.
To activate the Follow Me/Temp Sensing feature, point the remote control towards the
unit and press the Follow Me/Temp Sensing button. The remote display is actual
temperature at its location. The remote control will send this signal to the air conditioner
every 3 minutes until pressing the Follow Me/Temp Sensing button again. If the unit does
not receive the Follow Me/Temp Sensing signal during any 7 minute interval, the unit will
beep to indicate the Follow Me/Temp Sensing mode has ended.
AUTO-RESTART
If the unit shuts off unexpectedly due to power loss, it will restart with the previous function
setting automatically when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted in the first 3 minutes. This is to protect the
unit. Operation will automatically start after 3 minutes.
AIR FLOW DIRECTION ADJUSTMENT
The louver can be adjusted automatically. Adjust the air flow direction automatically (NOTE:
On some models the louver can be adjusted manually only) :
-When the Power is ON, the louver opens fully.
-Press the SWING button on the panel or remote controller to initiate the Auto swing
feature. The louver willl swing up and down automatically.
-Please do not adjust the louver manually.
Water drainage
-During dehumidifying modes, remove the
upper drain plug from the back of the unit,
install the drain connector(5/8" universal
female) with 3/4" hose(locally purchased).
For the models without drain connector,
just attach the drain hose to the hole.
Place the open end of the hose directly
over the drain area in your basement floor.
Remove the
upper drain plug
Continuous
drain hose
-During heating pump mode, remove the lower
drain plug from the back of the unit, install the
drain connector(5/8" universal female) with 3/4"
hose (locally purchased). For the models without
drain connector, just attach the drain hose to the
hole. Place the open end of the Hose adaptor
directly over the drain area in your basement
floor.
NOTE: Make sure the hose is secure so there
are no leaks. Direct the hose toward the drain,
making sure that there are no kinks that will stop
the water flowing. Place the end of the hose into
the drain and make sure the end of the hose is
down to let the water flow smoothly.(See Figs
with
. Do never let it up.(See Figs with ).
When the continuous drain hose is not used,
ensure that the corresponding drain plug and
knob are installed firmly to prevent leakage.
drain hose
adaptor
-When the water level of the bottom tray reaches
a predetermined level, the unit beeps 8 times,
the digital display area shows "P1" . At this time
the air conditioning/dehumidification process will
immediately stop. However, the fan motor will
continue to operate(this is normal). Carefully move
the unit to a drain location, remove the bottom drain
plug and let the water drain away. Reinstall the bottom
drain plug and restart the machine until the "P1"
symbol disappears. If the error repeats, call for
service.
NOTE: Be sure to reinstall the bottom drain plug firmly
to prevent leakage before using the unit.
11
13
CEP-081A, 101A, 121A
Remove the
lower drain plug
Continuous
drain hose
drain hose
adaptor
X
drain hose
X
adaptor
www.coastair-ac.com