ASSEMBLY INSTRUCTIONS
2. Extend the hanger bars to the width of the framing. Position the
ventilator with the bottom edge of the hanger bar tabs are flush with
the bottom edge of the framing, holding the ventilator in place.
Secure hanger bars to framing using one screw on each end of
hanger bar. Select a proper hole and secure the hanger bars
together using one screw.
3. INSTALL ROUND DUCTWORK
Connect the round ductwork (not included) to the damper / duct
connector, and run the ductwork to a roof or wall cap (not included).
Using tape (not included), secure all the ductwork connections so
that they are air tight.
The ducting from this fan to the outside of building has a strong
effect on the air flow, noise and energy use of the fan. Use the
shortest, straightest duct routing possible for best performance, and
avoid installing the fan with smaller ducts than recommended.
Insulation around the ducts can reduce energy loss and inhibit mold
growth. Fans installed with existing ducts may not achieve their rated
air flow.
CONNECT ELECTRICAL WIRING
Run 120V AC house wiring to the location of the fan. Use only UL- approved connectors (not included) to attach the house
wiring to the wiring plate. Refer to the wiring diagram, and connect the wires as shown.
AP200D-S
ON/OFF
SWITCH
BLK
WHT
LINE
GRD
IN
SWITCH BOX
AP200DH-S
HUMIDITY
SWITCH BOX
INSTALL GRILLE
Install ceiling material to complete the ceiling construction.
Then, cut around the fan housing.
To attach the grille assembly to the fan housing. Pinch the grille
springs on the sides of the grille assembly, and position the grille
into the housing with the grille springs in the appropriate slots.
Push the grille assembly towards the ceiling to secure.
BLK
FAN
WHT
GRD
UNIT
FAN
BLACK (BLK)
FAN
SWITCH BOX
POWER SUPPLY
120V AC
BLACK(BLK)
BROWN(BRN)
HUMIDITY
SENSOR
FAN
SWITCH BOX
POWER SUPPLY
120V AC
3
WHITE (WHT)
GROUND (GRD)
UNIT
WIRING
PLATE
FAN
RECEPTACLE
WHITE(WHT)
GROUND (GRD)
WIRE
UNIT
PANEL
FAN
RECEPTACLE
HUMIDITY
SENSOR
RECEPTACLE
screw