AKT BLSD-D-02-S Manuel - Sayfa 10
DC Sürücüler AKT BLSD-D-02-S için çevrimiçi göz atın veya pdf Manuel indirin. AKT BLSD-D-02-S 11 sayfaları. Brushless dc motor drivers low voltage bldc driver
BK: when NW=0,0: external BK low level effective 1: external BK high level effective
when NW=1,0: BK ineffective 1: BK effective
NW1: 0: external control effective (EN,FR,BK) 1: internal effective
NW: 0: Speed external effective, 1:speed internal internal effective(under panel speed adjusting mode, PWN speed
adjusting mode and segmental speed adjusting mode, it must set to 1)
KHX: stall alarm under the open loop w/sense mode. 0: stall alarm 1: NO alarm
HR60:
0: 120° hall control
KH:
0: closed loop control
For example:
1. Write 1500 speed
01 06 80 05 DC 05 28 C8
2. Write 2 pair of poles EN start
01 06 80 00 19 02 2A 5B
3. Write EN stop
01 06 80 00 18 02 2B CB
4. Write brake
01 06 80 00 1D 02 28 9B
5. Checking the fault state
01 03 80 1b 00 01 DD CD
6. 01 06 80 00 19 02 2A 5B
7. 01 06 80 05 D0 07 AC 09 Write 2000
8. 01 06 80 05 E8 03 BE 0A Write 1000
9. 01 60 80 00 18 02 2B CB
10. 01 06 80 00 19 01 6A 5A
The write message is explained as follows
Message
01
10
00 1B
00 05
0A
02 58
02 58
www.aktmotor.com
1: 60° hall control temporarily not supported
1: open loop control
EN start 2 pair of poles
EN stop
1 pair of pole EN start
Explain
address
Function code
Start address register
The numbers of register
Total byte digits
Write the first register data
Write the second register data
9
AKT Automation Technology