Aktobis WDH-520EB Kullanım Kılavuzu - Sayfa 5
Nem Alıcı Aktobis WDH-520EB için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Aktobis WDH-520EB 9 sayfaları.
Ayrıca Aktobis WDH-520EB için: Kullanıcı Kılavuzu (16 sayfalar)
Instructions for use:
1. Commissioning
1.1 Insert the mains plug properly into the socket.
1.2. Check that the condensation tank is properly seated in the dehumidifier. (When using the
dehumidifier for the first time, the "condensation tank full" light may come on. Simply pull
the condensation tank out briefly and then push it right back in and you are ready to go).
1.3 Switch on the unit with the power switch. Now press the humidity setting button and set your target humidity as
desired. The target value of 30% humidity actually corresponds to continuous operation ! The value you set
must be below the current room humidity for the unit to dehumidify. If your value is above the current room
humidity, the fan runs for 3 minutes and the unit then switches off. If the room humidity rises above the set
value, the unit automatically starts dehumidifying again.
1.4 Select between a low and a high fan strength / air circulation with the "FAN" button.
1.5 If you want to activate/use the timer function (function for determining the remaining time or function for
specifying a start time), press the TIMER key.
Determining the remaining running time: Press the TIMER button during operation to select the desired
remaining running time of the dehumidifier. (A value between 1 - 12 hours can be selected). After this selected
operating time has elapsed, the unit switches off automatically.
Determining a start time: When the dehumidifier is switched off, press the TIMER button to select the desired
start time. (A value between 1 - 12 hours can be selected). After this selected time has elapsed, the appliance
switches on automatically (with the last settings used, provided the mains plug has not been disconnected in
the meantime).
2. Emptying the collection tank / When the "Bucket Full" light is on
When the condensation tank is full, the signal light lights up and the dehumidifier then
automatically stops its dehumidification operation. Remove the condensation tank and empty
it. After you have pushed the condensation tank neatly back into the unit, the
dehumidification operation starts again automatically.
3. Connecting a hose
3.1. You will need a ½ inch plastic hose.
3.2. Briefly remove the condensation tank and push out the pre-punched plastic cover
(connection point for drain hose) with a large screwdriver.
3.3. Pass the plastic hose through the rear opening and then connect it to the drip tap (see diagrams below). Then
push the condensation tank neatly back into the appliance.
Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
Email: [email protected]