American Safe Room ASR-200-AV-NBC Safe Cell Kurulum ve Kullanım Kılavuzu - Sayfa 13
Hava Temizleyici American Safe Room ASR-200-AV-NBC Safe Cell için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. American Safe Room ASR-200-AV-NBC Safe Cell 19 sayfaları. Nuclear, biological, and chemical overpressure filter system
Optional hardware
Connection kits
We manufacture the most commonly needed connection kits for connecting your Safe Cell to an
external air supply. These kits may also be used where an air exhaust port is required for sealed
rooms or bunkers that employ the overpressure relief valve.
All of the connection kits accept the quick connect hose coupling of the filter/ventilation unit or the
mounting of the overpressure relief valve when an exhaust is required.
Backup hand operated air pumps
The ASR-200-AV-NBC Safe Cell is equipped with an internal automatic
switching power supply. This system automatically switches the Safe
Cell to the user supplied 12 volt automotive battery in case of failure of
the main AC power. A fully charged 125 amp hour deep cycle battery
will operate the Safe Cell for 16 to 24 hours before it needs to be
recharged.
For your added safety in case of a long term electrical power failure we
manufacture the two emergency backup hand operated air pumps - a
bellows type pump and a hand crank pump.
Overpressure valve
Used when the Safe Cell is installed into a location that provides no
other means for expelling the carbon dioxide (Co
occupants exhale. It meters the air out in a controlled quantity to
maintain overpressure and provide true ventilation (air in/air out). The
part numbers for the overpressure valves is ASR-50-OP (preset airflow)
and ASR-100-AOP (adjustable airflow).
These well sealed protected spaces usually include concrete safe
rooms, underground bunkers or steel enclosures. Most residential and
commercial homes and buildings are not sealed up enough to warrant
an overpressure valve - but this needs to be determined by testing the
protected space after the installation of the Safe Cell. If you have a
protected space that is not properly sealed, taking additional measures
to seal it up and installing an overpressure relief valve is the best way
to ensure your safety—air should have one way in (through the filters
in the Safe Cell) and one way out (metered through the overpressure
relief valve).
Blast valve
The automatic two way explosion resistant blast valves offers external
blast protection up 101 PSI. They are designed to be used in hardened
shelters. This rating is for both pressure and vacuum. Part number:
ASR-101-BV
Differential pressure gauge
Provides an accurate display of the difference in air pressure between
your protected space and the outside air in real time.
Part number: ASR-05-DPG.
ASR-200-AV-NBC Safe Cell
Installation and Operation Manual
Revision C - April 27, 2016
) and moisture that
2
Section
J
Page 13