AMERICAN SPECIALTIES 0198-2 Kullanım Talimatları ve Parça Kılavuzu - Sayfa 7
Kurutucu AMERICAN SPECIALTIES 0198-2 için çevrimiçi göz atın veya pdf Kullanım Talimatları ve Parça Kılavuzu indirin. AMERICAN SPECIALTIES 0198-2 10 sayfaları. Surface -mounted h igh -speed hand dr yer
7
1-
" [31]
7
32
1-
"
64
[28]
15
3-
"
16
[100]
9
7-
"
32
[185]
29
"
32
[23]
7
2-
"
16
[62]
11
" [18]
REF
16
19
2-
" [59]
64
SPECIFICATION
Surface Mounted Hand Dryer shall operate automatically from IR sensor that shall activate dryer when hands are placed in
sensor zone. Motor and heating element shall have internal resetting automatic thermal protection. Cover shall be fabri-
cated of one-piece, 16 gauge (.063", {1.6}) thick drawn steel or type 304 stainless steel and shall have all exposed surfaces
finished with acid, chip and scratch resistant porcelain enamel on steel or bright or satin finish on stainless steel. Fixed di-
rectional air vanes shall be heavy duty, rust proof and tamper resistant. Air intake slots shall not allow access to internal
parts. Back plate shall be furnished with vibration isolating mounting bushings. Circuitry shall have self-adjusting time-out
and fail-safe off protection controlled by a microprocessor that shall detect and reject false signals and shall automatically
self calibrate to provide uniform sensitivity over its entire life span. Entire unit shall be internally electrically grounded.
Dryer unit shall have C
U
L
®
Unit shall be warranted
Surface Mounted Sensor Hand Dryer shall be Model
Road, Yonkers, NY 10701-4913
INSTALLATION
Surface mount unit on wall with four (4) 1/4" screws, washers and bushings (supplied) through rubber grommets (supplied)
in a corrosion protected formed heavy steel back plate into suitable prepared mountings (by others) or other suitable mount-
ing hardware (by others) to suit wall conditions. For masonry walls use expansion bolts or anchors for 1/4" (6) screws.
Electrical service is supplied and connected (by others) prior to installing cover. Cover is secured to back plate with two (2)
hex socket security screws (supplied). For compliance with ICC/ANSI A-117.1-2003 and ADA Accessibility Guidelines
install unit with bottom of unit 48" (1219) maximum above finished floor (MAX AFF) if clear floor access is provided or
46" (1168) MAX AFF if side reach access over an obstruction (e.g. vanity) with reach depth greater than 10" (254) and less
than 25" (635) is only provided or 44" (1118) MAX AFF if forward reach over an obstruction (e.g. commode) with reach
depth greater than 20" (508) and less than 25" (635) is only provided. For general utility install unit so that sensor lens is 54"
to 56" (1372-1422) AFF. For installation of two or more dryers, dryers should be no closer than 24" (610) on center.
OPERATION
User activates dryer by placing hands under sensor. Dryer automatically shuts off after time-out when user removes hands
from sensor zone.
THIS MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES IN DESIGN OR DIMENSIONS WITHOUT FORMAL NOTICE
AMERICAN SPECIALTIES, INC.
441 Saw Mill River Road, NY 10701
(914) 476.9000 • (914) 476.0688
www.americanspecialties.com
SURFACE MOUNTED SENSOR HAND DRYER (PG 1/2)
7
14-
" [367]
16
11
12-
" [322]
16
21
9-
" [237]
64
53
2-
"
64
7
5-
" [138]
16
[72]
27
9-
" [250]
32
US approval and be listed under the re-examination services of Underwriters Laboratories, Inc.
against defects in materials or workmanship for ten (10) years.
MODEL
ISSUED:
REVISED:
7
" [23]
8
9
2-
" [54] REF
64
MOUNTING
HOLES
FOUR (4)
PLACES
7
" DIA [Ø22]
8
ELECTRICAL
KNOCKOUT
FOUR (4)
PLACES
37
1-
" [40] REF
64
0185 of American Specialties, Inc., 441 Saw Mill River
: 0185
10/05
01/10
15
3-
" [100]
16
13
10-
"
16
[275]
NOTE:
ALL DIMS
INCH [MM]
Patented No. D 543,661 S