GENERAL INSTALLATION OF THE VIGILANTE™
The Vigilante™ will install into any standard ASA adapter. Air America® has maintained the same
high quality CGA 320 thread profile (ASA adapter thread profile) throughout the UNIREG® series of
regulators.
The use of the appropriate pressure rated steel elbows and disconnects are required when choosing
the hardware to connect your Vigilante™ to your Air/Nitrogen/CO2 system. Many of the fittings that are readily
available in your local hardware store are made of brass or nickel plated brass. While these fittings may be
attractive in price, they pose a serious safety hazard due to an inadequate pressure rating and lack of impact
resistance.
After attaching the appropriate fittings to your Vigilante™ and having mounted it on your marker the
initial pressure adjustments can be made. Each Vigilante™ leaves the factory preset at 750 PSI. Before
applying pressure to your system, read the manufacturers suggested inlet pressure for your marker. If the
suggested inlet pressure is below 700 PSI or you are not sure of what the required inlet pressure for your
marker is, please follow the steps below and in the next section before making any adjustments.
The delivery pressure to your marker is adjusted by turning the adjustment nut on the top of the
Vigilante™. You will need a 3/16 hex or allen key for this operation. Turning the nut clockwise will increase
the delivery pressure, while turning it counter clockwise will decrease the delivery pressure. Please note that
when you decrease the pressure setting you must cycle your marker several times after each adjustment.
This will allow the previously regulated pressure to be exhausted and allow your system to stabilize at its new
setting.