American Standard TownSquare 2555.602 Kurulum Talimatları
Sıhhi Tesisat Ürünleri American Standard TownSquare 2555.602 için çevrimiçi göz atın veya pdf Kurulum Talimatları indirin. American Standard TownSquare 2555.602 3 sayfaları. American standard plumbing product user manual
Ayrıca American Standard TownSquare 2555.602 için: Kurulum Talimatları (3 sayfalar)
TOWNSQUARE
PRESSURE BALANCING BATH AND
SHOWER-Built-in Diverter for TUB FILLER
with
EverClean™ Finish
Congratulations on purchasing your American Standard faucet with
EverClean finish found only on American Standard faucets.
EverClean Finish
• One wipe effortlessly removes spots
• Eliminates the need for cleaners and scrubbing
• Permanent surface protectant remains beautiful
for the life of the faucet
• EverClean™ available on: Polished Chrome, Satin Nickel,
Stainless Steel, Polished Brass (or any combination of these finishes)
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Required Tools
Phillips Screwdriver
Flat Blade Screwdriver
Plumbers' Putty or Caulking
Channel Locks
Adjustable Wrench
1
ROUGHING-IN
When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When finished soldering,
NOTE
flush valve body, replace cartridges, check stops (if present) and plaster guard to continue installation. Use thread
sealant or Teflon tape on threaded connections.
See Roughing-in diagram before starting.
Connections are:
1/2" female NPT for threaded inlets
Connect RISER PIPE (1) to MANIFOLD (2)
top outlet marked "SHR".
Connect TUB FILLER PIPE (3) at bottom
outlet marked "TUB".
For proper positioning the finished wall
must be within side wall of PLASTER
GUARD (4).
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to wall, note
roughing-in dimensions.
FINISHED WALL
2" REF.
8" REF.
74" FOR
HEAD CLEARANCE
7-1/2"
18"
OPTIONAL
7-1/4" REF.
TOP OF
TUB RIM
BOTTOM OF
TUB
CAUTION
Turn off water at main supply.
If the valve is installed on a fiberglass
or other thin wall application, the
PLASTER GUARD (4) can be used as a support.
Cut a 4" dia. hole in the shower stall.
Drill two additional 1" holes to allow access
to the stops.
Remove PLASTER GUARD (4), rotate 180˚
so that indicated screw holes fit MANIFOLD (2).
Push CAP on valve, place ESCUTCHEON on and
attach with screws.
Connect hot and cold water supplies.
Cap off shower pipe (5) and tub filler pipe (6).
For support, use pipe BRACES (7) secured to wooden braces.
With valve turned off, turn on water supplies. Check for leaks.
Installation
Instructions
2555.602
1-5/8" TO 3-1/4"
1
1/2" I.P .S.
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
65'' AND 78''
"SEE ILLUSTRATION"
SHW
TUB
1/2" NPT
1
4"
Certified to comply with ANSI A112.18.1
M 9 6 8 7 8 9 R e v. 1 . 2
OUTLETS 1/2" NPT
5-5/8"
5-5/8"
INLETS
1/2" NPT
THREADED INLETS (STOPS)
1
2
COLD
HOT
3
1-3/4"
5
7
4
6