Domus Ventilation HRXE Kurulum Talimatları Kılavuzu - Sayfa 6

Fan Domus Ventilation HRXE için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Domus Ventilation HRXE 8 sayfaları. Mechanical ventilation units with heat recovery

Domus Ventilation HRXE Kurulum Talimatları Kılavuzu

5.0 ELECTRICAL CONNECTION

For good EMC engineering practice, any sensor cables or switched
live cables should not be placed within 50mm of other cables or
on the same metal cable tray as other cables.
The electrical connection of the unit must be carried out by a
qualified electrician.
14
Note: Wiring is for
reference purposes
only as the connections
shown are factory fitted.
The unit is pre-wired
with a 2 metre fly lead.
5.1 Wiring - Unit Serving Kitchen and Bathroom
Disconnection from the
15
supply mains must be
incorporated within the
fixed wiring in accordance
with the wiring regulations
and shall have a minimum
contact separation of 3mm.
5.2 Wiring - Unit Serving Kitchen and Two Bathrooms
16
Disconnection from the
supply mains must be
incorporated within the
fixed wiring in accordance
with the wiring regulations
and shall have a minimum
contact separation of 3mm.
LAB1355R | SEPTEMBER 2018
PCB Details
MAINS
230V
N
50Hz
L
Fuse 2A
Light
switch
(Double
Pole)
Kitchen switch
MAINS
230V
N
50Hz
L
Fuse 2A
Light
switches
(Double
Pole)
Kitchen switch
Electrical details:-
Voltage: 240V 1ph 50Hz
Consumption: 1.2 Amp
Fuse rating: 3 Amp
This unit must be earthed.
The cable from the mains power supply should be connected to a
fixed wiring installation, via a fused isolator, in accordance with
current IEE wiring regulations.
Room
light
3 Pole
isolator
Room
lights
3 Pole
isolator
Green/yellow
Blue
Brown
Black
Grey
Optional 3 speed switch
Green/yellow
Blue
Brown
Black
Grey
Optional 3 speed switch
Supply cord
from unit
Supply cord
from unit
PAGE 6