READ AND FOLLOW ALL INSTRUCTIONS
FOR FUTURE MAINTENANCE, A
REMOVABLE PANEL IS PROVIDED TO
ACCESS THE BLOWER
1. READ THESE INSTRUCTIONS AND RULES CARE-
FULLY. FAILURE TO FOLLOW THEM COULD CAUSE A
UNIT MALFUNCTION. WARNING! A MALFUNCTION
COULD CAUSE SERIOUS BODY INJURIES, AND/OR
PROPERTY DAMAGES.
2. CHECK YOUR LOCAL ELECTRICAL SAFETY AND
PLUMBING CODES. THE INSTALLATION MUST
COMPLY WITH THESE GUIDELINES.
3. NO MODIFICATIONS, ADDITIONS OR DELETIONS
SHOULD BE MADE TO THE ELECTRONIC CONTROL
WITHOUT FACTORY APPROVAL.
4. THIS ELECTRONIC CONTROL SHOULD NOT BE
LOCATED NEAR A HEAT SOURCE EXCEPT PUMPS.
BLOWERS OR OTHER ELECTRONIC CONTROLS.
5. WIRING SHOULD BE PERMANENT. DO NOT USE AN
EXTENSION CORD. HAVE THE ELECTRICAL PART OF
THE INSTALLATION DONE BY, OR APPROVED BY, A
QUALIFIED ELECTRICIAN.
6. ALWAYS SHUT OFF THE ELECTRICAL POWER TO
THE BREAKER PANEL BEFORE SERVICING.
7. ENSURE THAT A CLASS A GROUND FAULT CIRCUIT
INTERRUPTER (G.F.C.I.) IS INSTALLED AS PART OF
THE WIRING.
757222-A
Operating Instructions - Therapeutic System

INSTALLATION

1. FOR AN ELECTRONIC CONTROL NOT PROVIDED
WITH NEMA PLUGS. CONNECT THE FACTORY PRE-
INSTALLED 14/3 TYPE SJ CABLE TO A JUNCTION BOX
(NOT PROVIDED BY THE MANUFACTURER). DEPEND-
ING ON YOUR MODEL, RUN A SEPARATE 120V, 60HZ,
20A MAX OR 230V, 50HZ, 10A MAX, OR 240V, 60HZ,
15A MAX G.F.C.L. (CLASS A PROTECTED) ELECTRIC
CIRCUIT FROM THE MAIN FUSE BOX TO THE JUNC-
TION BOX. USE A 14 GAUGE CABLE WITH 3 CONDUC-
TORS (2 WIRES PLUS GROUND) IN CONNECTIONS
UP TO 100 FEET (30.4M) FROM THE MAIN FUSE BOX.
REFER TO YOUR LOCAL ELECTRICAL CODE IF YOUR
DISTANCE BETWEEN THE INSTALLATION SITE OF
THE BATHTUB UNIT AND THE MAIN FUSE BOX IS
MORE THAN 100 FEET (30.4M).
2. LOCATE THE SIDE TO BE PLACED ON TOP AS INDI-
CATED ON THE CONTROL BOX (UP/HAUT). FIX THE
ELECTRONIC CONTROL BOX FIRMLY WITH TWO
SCREWS.
3. CONNECT THE KEYPAD CABLE TO THE CONTROL
BOX CABLE (INDICATED BY THE WORD "KEYPAD" ON
THE CONTROL BOX).
4. CONNECT THE POWER OUTPUT CABLE TO THE
BLOWER OR PUMP. USE A JUNCTION BOX IF YOUR
ELECTRONIC CONTROL AND/OR BLOWER OR PUMP
ARE NOT PROVIDED WITH MOLDED PLUGS.
5. CONNECT THE TERMINAL LUG ON THE HEATSINK TO
THE GROUND WITH A UNINSULATED WIRE OF 8
GAUGE MINIMUM.
6. VERIFY CONNECTION AND FUNCTIONING OF ALL
COMPONENTS OF THE SYSTEM BEFORE FINALIZING
THE INSTALLATION.
7. THE AUXILIARY OUTPUT OPTION, MAKES IT POS-
SIBLE TO CONNECT AN EQUIPMENT OF 120VOLTS /
0,5AMP MAXIMUM. (ONLY AVAILABLE WITH
120V/60HZ CONTROL).
(7)