CONTOUR
ELECTROL
®
®
120V WIRING DIAGRAM
FOR STANDARD
WALL SWITCH
JunCTIon BoX
loCATED In lEfT EnDCAP
gRounD–MuST BE ConnECTED
To BuIlDIng gRounD
AC (CoMMon)
SPDT SWITCH WITH
CEnTER off
BlACK
uP
AC HoT 120VAC 60HZ 1 AMP
off
BlACK/YElloW
DoWn
RED
noTE: A SInglE SWITCH CAnnoT BE uSED To oPERATE MoRE THAn
onE SCREEn. ConTACT THE fACToRY foR fuRTHER
THIS SWITCH CAn noT
InfoRMATIon.
BE uSED WITH lVC.
120V WIRING DIAGRAM WITH
OPTIONAL BUILT-IN VIDEO
PROJECTOR INTERFACE
CAUTION: THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER
WIRES TO THE PROJECTOR. FAILURE TO DO SO MAY DAMAGE THE CONTROLLER.
use 2-conductor 20-24 gauge wire to extend the low voltage connection from
the projector's 5 or 12-volt screen trigger output to the length required to reach
the VPI. When extending the low voltage connection from the projector's screen
trigger output polarity does not matter. The red and black wires from the VPI are
interchangeable.
IMPORTANT NOTE:
The wall switch is REQuIRED to make any limit switch adjustments,
EVEn if a third party control system is used. Therefore, it is advised to
wire the switch or provide a 3-conductor connection that is accessible.
240V WIRING DIAGRAM WITH
OPTIONAL BUILT-IN VIDEO
PROJECTOR INTERFACE
CAUTION: THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE TRIGGER WIRES TO
THE PROJECTOR. FAILURE TO DO SO MAY DAMAGE THE CONTROLLER.
1.
use 2-conductor 20-24 gauge wire to extend the low voltage connection from the
projector's 5 or 12-volt screen trigger output to the length required to reach the VPI.
When extending the low voltage connection from the projector's screen trigger output,
be sure to maintain the proper polarity. The red wire from the VPI is the "signal" and the
black wire from the VPI is the "ground" .
2.
Connect the wires from the VPI that are labeled "low Voltage Connection" to the end
of the extended screen trigger wires above.
INSTALLATION
FIGURE 6
WHITE
BlACK
MoToR
RED
gREEn
gRounD To CASE
FIGURE 8
fRonT of
WAll SWITCH
FIGURE 9
240 VOLT WIRING DIAGRAM FOR STANDARD
WALL SWITCH:
Da-lite offers two styles of 240 volt wall
switches for standard operation. Please see
wiring diagram included in wall switch box
included with screen.
lED
RJ-22
uP lIMIT
InPuTS
TACTIlE
BuTTon
RJ-22
JACK
U P
S T O
P
DoWn
lIMIT
D O W
N
TACTIlE
BuTTon
BACK of
WAll SWITCH
BlACK
RED
5/12 VolT SCREEn
TRIggER on PRoJECToR
BRoWn
(HoT)
BluE
240VAC/50HZ
PoWER SouRCE
gREEn/YElloW
(gRounD)
RED
BlACK
WHITE
fRonT of
BACK of WAll
WAll SWITCH
SWITCH
uP
SToP
DoWn
5
RJ-22 JACK
RJ-22 ouTPuT
DRY ConTACTS
RJ-45
JACK
DATA
CABlE
RJ-45
RECEPTAClE
PoWER
WIRE
VPI TRIggER
gREEn (gRounD)
MoDulE
BlACK (HoT)
gRounD–MuST BE ConnECTED
WHITE (CoMMon)
To BuIlDIng gRounD
POWER INPUT 120VAC / 60HZ
gREEn/YElloW
BRoWn
BluE
(CoMMon)
BlACK (uP)
(CoMMon)
RED
BlACK
5/12 VolT SCREEn TRIggER on PRoJECToR
FIGURE 7
(gRounD)
(DoWn)