REPAIR PARTS LIST
Repair parts are determined by toilet tank number which can be found marked inside tank.
NOTE: "XXX" represents color or trim finish options. Specify when ordering.
PART NO.
738772-XXX0A
735105-XXX0A
5325.010.XXX
7381125-400.0070A
7301111-0070A
3280.040-0070A
738826-0070A
738570-1020A
738985-0070A
738963-XXX0A
738126-XXX0A
5260.012.XXX
7301134-XXX0A
034783-XXX0A
072989-0070A
PROBLEM
Does not flush
a. Water supply valve closed.
b. Supply line blocked.
c. Flush valve chain too loose or disconnected.
d. Sand or debris lodged in water control.
Poor or sluggish flush
a. Bowl water level too low.
b. Supply valve partly closed.
c. Partially clogged trapway and/or drain pipe and/or vent.
d. Supply pressure too low.
e. Flush valve chain too tight, holding flush valve open.
Toilet leaks
a. Poor supply line connection.
b. Poor bowl to tank/floor connection.
Toilet does not shut off
a. Flush valve seal leaking or deformed.
b. Sand or debris lodged in water control.
DESCRIPTION
®
Champion
4 Trip Lever Assembly
®
Champion
4 Chinaware Tank Cover
®
Champion
4 Seat
®
Champion
4 Water Control Assembly
®
Champion
4 Valve Seal Kit
®
Champion
4 Flush Valve Assembly
®
Champion
4 Adapter Assembly - Kit #247
®
Champion
4 PVC Refill Tube
®
Champion
4 Clevis Pin Assembly
Traditional Trip Lever Assembly
Traditional Chinaware Tank Cover
Traditional Seat
Traditional Bolt Cap Kit
Bolt Cap Kit - #128
Refill Tube Clip
TROUBLESHOOTING GUIDE
POSSIBLE CAUSE
a. Open valve and allow water to fill tank.
b. Shut off water supply, disconnect supply line and inspect all
gaskets and washers. Reassemble. Also, see Fluidmaster
maintenance. (see Step 13)
c. Readjust chain length as required.
d. Shut off water supply. Remove cap and clean as per Step 13.
a. Check that refill tube is connected to water control and
inserted into tank overflow without being kinked or damaged.
(see Step 11a)
b. Open supply valve fully. Be sure that proper supply tube size
is used.
c. Remove obstruction. Consult a plumber if necessary.
d. Normal supply pressure must be at least 20 psi.
e. Readjust chain length as needed. Review Step 9b.
a. Review Step 8 of installation procedure.
b. Review Step 4 through 6 of installation procedure.
a. Clean debris from seal surface. Replace flush valve seal as
needed. (see Step 11)
b. Shut off water supply. Remove cap and clean as per Step 13.
- 4 -
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
CORRECTIVE ACTION
7 3 0 8 6 5 - 10 0 Rev. M
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔