220V Wiring Diagram with Optional Built-In Low Voltage Control
220V Wiring Diagram with Operation & Limit Adjustment Wall
Switch
3-conductor 20–24 gauge wire can be used in place of the supplied
RJ-14 cable to connect the wall switch. Connect the BUS terminals on
the wall switch to the corresponding BUS terminals on the splitter
board.
Up Limit
Tactile Button
U P
S T O P
D O W
U P
N
S T O
Down Limit
D O
W N
Tactile Button
Front of
Wall Switch
RJ-22 Jack
(Connection to
Wall Switch)
RJ-14 Pin-Outs
(Tab Is Facing Down)
Bus (RP Data)
White
RQ Data
Green
+5V
Red
Ground
Black
Supplied RJ-14 cable
U P
S T O
P
D O
W N
LED
P
Bus
Back of
Wall Switch
RJ-22
Jack
RJ-22 Pin-Outs
Bus (RP Data)
RQ Clock
Standard RJ-22 can be used in place of RJ-14 cable
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit
switch adjustments, EVEN if a third party control system is used.
Therefore, it is advised to wire the switch or provide a 3-conductor
connection that is accessible.
RJ-22
Output
RJ-22
Inputs
RJ-45 Jack
Power
Wire
Brown
(Common)
Blue
(Hot)
Power Input 220VAC / 50Hz
(Tab Is Facing Down)
+12V
Blue
Yellow
RQ Data
Green
+5V
Red
Ground
Black
White
Up (Dry Contact)
Down (Dry Contact)
Common (Both)
Bus (Bus)
5V (Bus)
RJ-45
Receptacle
Data
Cable
Green / Yellow (Ground)
RJ-45 Pin-Outs
Manual 2
+12V
Bus (RP Data)
RQ Data
+5V
Ground
RQ Clock
Manual 1
(Tab Is Facing Down)
Brown
Blue
Yellow
Green
Red
Black
Orange
Purple
9