American-Lincoln ALTO SMART 2000 Elektrik Sorun Giderme Kılavuzu - Sayfa 8
Yıkayıcı American-Lincoln ALTO SMART 2000 için çevrimiçi göz atın veya pdf Elektrik Sorun Giderme Kılavuzu indirin. American-Lincoln ALTO SMART 2000 14 sayfaları. Sweeper/scrubber
Conditions necessary for circuit to work
1. Battery voltage
2. Key switch on
3. CB-10,CB-12 & CB-13 closed
4. Hopper switch closed when hopper is open.
5. FU1 Closed
6. Seat switch closed.
7. Solenoid (1A) closed
8. Hopper switch in up or down position.
FU1
120 AMP
1,C,E,K
21A
CB-13
3B,
3C
3
15A
21,
21A
1
CB-10
2
15A
IGN.
ACC.
KEY SW .
CB-12
15
26
15A
American-Lincoln Technology
SMART 2000 Electrical Troubleshooting Guide
CHIME & HOPPER ACTUATOR CIRCUIT
36 V BATTERY BANK
1A
B
A
26
HOPPER SW.
NO HELD CLOSED
WHEN HOPPER
5.1K ,1 WATT
NO
RESISTOR
21B
NC
9
SEAT SWITCH
4A
UP
16
7A
MTR.
17
DOWN
CHIME & HOPPER ACT. CIRCUIT
-
+
TO BROOM SWITCH
9A
IS CLOSED
CHIME
39
2ND MOTOR SOLENOID
HOPPER SW.
NC HELD OPEN
WHEN HOPPER
IS CLOSED
RED
HOPPER ACT.
YEL
7F
7H
7A
7