Dontek Electronics V2TC Kurulum Talimatları - Sayfa 2
Kontrolör Dontek Electronics V2TC için çevrimiçi göz atın veya pdf Kurulum Talimatları indirin. Dontek Electronics V2TC 2 sayfaları. Digital solar controller
WARRANTY – V2TC
This range of product is covered by a limited 3 year warranty against component
failure or faulty workmanship from the date of installation.
A faulty unit should be returned in the first instance to the dealer from which the
unit was purchased.
Damage to the unit due to misuse, power surges, lightning strikes or installation that
is not in accordance with the manufacturer's instruction may void the warranty.
Valves and actuators are covered by a twelve month warranty at the discretion of
their manufacturer.
Warranty does not cover travel costs to or from installation site.
Return to supplier for repair
Customer Record. (To be retained by the customer)
Dealer/Installer Name......................................................
Model Number...........................
Serial Number............................
Date Installed.............................
....................................................................................
For service assistance phone 1300 130 693
Dontek Electronics Pty Ltd
P.O. Box 239
Bayswater
Victoria 3153
www.dontekelectronics.com.au
MODEL V2TC Digital Solar Controller
OPERATING INSTRUCTIONS
Summer Mode (AUTO) is normal operating mode used during the Pool Swimming Season. You may
set the desired pool limit by pressing the UP or Down Buttons. The display shows the pool temperature
then flashes the limit setting and light, the pump light and pump will be on when solar gain is available.
Manual Mode (PUMP/MAN) is used to prime, clean or test the pump. To select manual mode press
the SELECT button until the PUMP/MAN light is illuminated. The pump will then start, or stop if it has
been running. To return to normal run simply press the SELECT button till the AUTO light is illuminated.
The V2 will automatically return to AUTO run after 30 minutes.
Roof Mode displays the roof sensor temperature, a hot roof indicates that solar gain (heating) is
available, if left unattended in this mode the V2 will automatically return to AUTO run after 3 minutes.
Winter Mode should be selected when the pool is not being used for extended periods. The pump will
be turned on for 3 minutes every day at the same time Winter Mode was selected. This will assist in the
systems off-season maintenance and save energy. To enter this mode press the SELECT button till the
WINTER light is illuminated. When a flow switch is used ensure the winter mode is activated during the
filter run times only. If the power is interrupted during winter mode the V2 will continue to count time
accurately.
Tropical Mode is used to assist in cooling over heated pools. If the limit has been exceeded, which is
indicated by the limit light on, and the roof temperature drops below the limit temperature (usually
some time late at night) the pump will turn on and pump pool water to the roof to cool it down. The
pump will turn off when the pool water is cooled to the limit setting. To set this function press the
SELECT button till the TROP light is illuminated. To switch back to Summer Mode press the SELECT
button till the AUTO light is illuminated.
Retro-Fit (Boosted) Systems - Optional
When solar gain is achievable the V2 Controller detects constant water flow from the main filtration
system, the Pump light will flash for thirty seconds and then the solar boost pump will start. When filter
back washing is to be carried out the power to the V2 controller must be turned off. If Winter Mode is
to be selected, ensure that it is set during normal filter times and the main filter pump is running.
Clock this model is fitted with a settable 24 hour clock, see installers section if adjustment is required.
Night time is indicated by a flashing AUTO light.
OPERATION
The V2 will turn the pump on when the roof temperature is higher than the pool (pipe) temperature by
8°C. When the pool temperature reaches the limit setting the limit light will turn on and the auto light
will flash, it will remain in this state for 4 hours. After 4 hours, and if solar heating is available the pump
is turned on for ~3 minutes to sample the pipe so an accurate pool temperature can be recorded, if
after 3 minutes the pool requires heating the pump will continue to run to heat the pool. If solar
heating is not available after the 4 hour wait a brief blink of the roof light is indicated. If the pump is
turned off due to the pool being at the set temperature limit, or if no heating is available on the roof
during day time operation, then the last accurate recorded pool temperature will be displayed for 6
hours from when the pump was last running. When the ~3 minute sample is active the pump/man light
will flash until this test is over. If an optional pressure switch is fitted the V2 will flash the pump light for
30 seconds when constant flow from the main filter pump is first detected, then start the booster pump.
In pressure switch mode no sampling occurs, the V2 waits until the pipe is below the set temperature
limit, indicated by a flashing auto light