Astra A5022 Kullanıcı Kılavuzu - Sayfa 4

Pusula Astra A5022 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Astra A5022 13 sayfaları.

1.3
Switch Inputs
Except for variants with suffix -S, two push-button switches are provided for calibrating the
compass in the field.
When the A5022 is viewed from the front face with the LED facing, then Switch 1 is on the right and
Switch 2 is on the left.
1
Switch 1:
2
Switch 2:
but at any azimuth. Pressing S2 sets the heading to zero and so can be done when the
whole installation is headed North.
3
Both together
calibration process to halt and restores the previously saved calibration values.

1.4 Indicator light

A blue light indicates three states of the A5022.
State 1
Uncalibrated
State 2
In the process of calibration
State 3
Calibrated
After the reset command
a long flash.
Note that the LED can be turned off and on by the DLED command – see section 5.
S2
Fig 1
Start the auto-calibration process
Set reference NORTH heading. The A5022 must be mounted upright
Pressing both together for at least one second causes the auto-
long flash
continuous
short flash
$PATC,IIHDG,0CV<CR><LF>
S1
, the A5022 is uncalibrated and will have
4