5. MOUNTING
Recomended height of control unit mounting
Fasteners choosen depending on the type of wall.
6. CONTROL UNIT OPERATION
6.1. OPERATING.
Turn the main switch to «I» position.
Check that the control unit power indicator lights, then press up button for lifting of dockleveler.
Keep the button pressed until complete lifting of DL. Then press button lip pull out and keep it pressed untill the extension of lip
becomes required length.
Press down button briefly and wait while the lip will come down to the truck body.
WARNING! Don't switch off power while dockleveler is being used. Only in case of emergency. Emergency stop
function integrated into the main switch. Use this function ONLY in case of emergency. It may not be used during
loading/unloading, as the dock leveller is unable to follow the vertical movements of truck which could lead to damage
of hydraulic system.
6.2. RETURN TO THE INITIAL POSITION
After finish of loading/unloading dock leveler has to back to initial position.
Press up button and lift dockleveler approx. 100mm higher from truck body.
Press and keep lip pull in button while the lip is not retract completely. Press down button briefly, dock leveler descend to park
position position. Turn off main switch to "0".
6.3. EMERGENCY STOP
In case of emergency turn the main switch to «0»
To resume dock leveler operation, make sure that the power is on, there is nobody under the deck or close to dockleveler movable
parts. Press up button briefly.
6
1...1,5 m
CONTROL UNIT OPERATION
Fix points