DABIR D2-202624-10-0H Kurulum Kılavuzu - Sayfa 2

Tıbbi Ekipman DABIR D2-202624-10-0H için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. DABIR D2-202624-10-0H 2 sayfaları.

DABIR D2-202624-10-0H Kurulum Kılavuzu
Cleaning / Disinfecting Procedures
Cleaning procedures listed below are recommended by Dabir and should be adjusted according to specific healthcare facility policy.
Aggressive cleaning measures may cause damage.
NOTE: It is the responsibility of the user to replace Surfaces when needed.
CAUTION: IMPORTANT CLEANING RELATED NOTES:
Always remove patient from Surface prior to cleaning.
Maintain accessibility to Power Cord such that it can be easily unplugged prior to cleaning and/or servicing.
Always turn Controller "OFF" during patient transfer, cleaning and before patient positioning.
Do NOT allow liquids or loose particle debris to enter or block any part of the Controller.
Keep Micropressure Surface vents free of any liquids or loose particle debris which may restrict air flow.
Sharp objects from any source may damage the Surface and compromise function.
After cleaning / disinfecting, allow Surface adequate time to fully dry before patient use.
It is the responsibility of the user to properly dispose of the Surface when damaged or soiled.
Do NOT use if product is damaged.
Do NOT autoclave.
Cleaning the Controller
Power "OFF" the Controller and disconnect the Power Cord from the wall outlet prior to cleaning. Remove visible soiling then
disinfect by wiping down all areas with a hospital grade disinfectant cleaner. Always allow proper contact drying time per the
disinfectant manufacturers instructions.
NOTE: Do NOT saturate cloth or apply fluids / liquids directly to the Controller to prevent fluid ingress of this sensitive electronic
medical device. Inspect Controller air intake and exhaust vents to ensure they are NOT obstructed by loose particle debris.
Cleaning the Micropressure Surface
With the Surface connected, remove visible soiling then disinfect by wiping down all areas with a hospital grade disinfectant
cleaner. Always allow proper drying time per the disinfectant manufacturers instructions. If excessive cleaning residue changes the
slip properties of the surface to an unacceptable level, wipe Surface down with a water moistened cloth to remove the residue and
disinfect again.
NOTE: Please refer to Dabir Operation / Service Technical Manual for a list of approved and unapproved cleaners.
Surface Disposal
Please follow Section 7 Cleaning Procedures prior to disposal in a landfill or per hospital standard procedure.
Applicable Micropressure (MP) Surface Models:
MODEL
Description
MN
D2-3S3384-05-1L
MP Surface - ICU/Med-Surg Bed (33"W x 84"L, 5' Hose)
D2-3S3384-10-1L
MP Surface - ICU/Med-Surg Bed (33"W x 84"L, 10' Hose)
D2-3S3384-16-1L*
MP Surface - ICU/Med-Surg Bed (33"W x 84"L, 16' Hose)
D2-3S2665-05-0L
MP Surface - Stretcher (26"W x 65"L, 5' Hose)
D2-3S2665-10-0L*
MP Surface - Stretcher (26"W x 65"L, 10' Hose)
D2-3S2665-16-0L*
MP Surface - Stretcher (26"W x 65"L, 16' Hose)
D2-3S2340-05-0H*
MP Surface - Crib (23"W x 40"L, 5' Hose)
D2-3S2340-10-0H
MP Surface - Crib (23"W x 40"L, 10' Hose)
D2-202624-05-0H*
MP Surface - Chair (26"W x 24"L, 5' Hose)
D2-202624-10-0H*
MP Surface - Chair (26"W x 24"L, 10' Hose)
*Special Order Only (Subject to availability)
Corporate Headquarters, Sales & Manufacturing:
Dabir Surfaces, Inc., 7447 West Wilson Ave., Harwood Heights, IL 60706, USA, www.dabir-surfaces.com
Sales Inquiries:
[email protected], Tel: +1(888)559-3641
Technical Support:
[email protected], Tel: +1(888)559-3642
DOC# R02-0006-00054-CA
2