ELECTRICAL CONNECTIONS

The electric installation must be made in accordance with C15100 and P91C by a
properly trained and qualified electrician.
Note : in Presence of an electrolysis in
salt the information contact 3 and 4
(contact closed = pool cover closed) will
be connected avoid up-chloration to the
water's swimming pool (See the
electrolysis's documentation for wiring)
1
1: Tubular motor
2: Electrical box
3: Key switch
4: Connexions
Note: The electrical box is located in the technical room of the swimming pool. Its
power pack is carried out by a cable 3×2.5², and of a tension of 220 Volts, is
protected by a differential circuit breaker from 30mA (not included)
Nota : in the case of a wiring of an electrolysis in salt.
Contact 1 = COMMUN
Contact 3 = Contact NORMALMENT CLOSED
Contact 4 = Contact NORMALMENT OPEN
2
10/17
Revision number B-007-2012-10-05