INSTALLATION OF THE EARTH ELECTRODE:

We recommend the installation of this electrode in order to measure the residual currents present in
the water.
Mounting the earth electrode:
Mount the earth electrode in the place on the chamber designed for this purpose.
Put the earth pin in place.
Connect the earth electrode to the pin with a braid of 16mm
NEVER USE AN EXISTING ELECTRICAL EARTH.
Earthing 20 mm
To independent earth
pin
Main drain
Pump
Reagent tank:
It is preferable to use liquid pH+ or pH- reagents as the case may be. We strongly advise against using
pH correctors in powder form or hydrochloric acid.
Place the reagent tank near to the control box and, if possible, avoid placing it directly underneath.
The end of the suction pipe with its suction strainer should be located approximately 2 cm above the
bottom of the tank.
Injection:
Place the injector rod on the salt chlorinator chamber in the dedicated housing.
Filter
Drain
6
2
minimum.
Dual pure
Chamber
Heater or
other
By-Pass
Número de revisión
Rev 001-2013-08-06
ENGLISH
Reagent Tank
Return to pool
By-Pass