Astria Polaris36ZEN Kurulum Talimatları Kılavuzu - Sayfa 13
Dış Mekan Şömine Astria Polaris36ZEN için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Astria Polaris36ZEN 16 sayfaları. Outdoor decorative gas fireplace
CHECKING APPLIANCE OPERATION
With gas line installed run initial system check-
out before installing any additional accesso-
ries. Follow the lighting instructions provided
in the Care and Operation Instructions.
NOTE: Lighting Instructions are also found on
the literature tag tied to the gas piping next
to the gas valve. To access the tag, open the
lower control compartment door (refer to
Figure 13 - Valve Access).
When first lighting the appliance, it will take
a few minutes for the line to purge itself of
air. Once purging is complete, the pilot and
burner will light and operate as indicated in
the instruction manual. Subsequent lighting
of the appliance will not require such purging.
Inspect the pilot flame (remove logs, if neces-
sary, handling carefully).
After the logs have been placed and the fireplace
has been checked for proper flame presenta-
tion, use the remaining volcanic stone to fill in
voids and spaces. Remember, you may need
to access the high/low flame control beneath
the refractory cover.
Electronic Appliance Checkout
To light the burner, turn 'ON' the remote wall
switch. The battery will energize a spark that
will light the pilot. The pilot flame will engulf
the sensor and open the main valve. Within
seconds the main burner will light. Ensure the
igniter lights the pilot. The pilot flame should
engulf the sensor as shown in Figure 17.
ELECTRONIC
Sensor
Igniter
Figure 17
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning are similar
to the flu with headaches, dizziness and/
or nausea. If you have these signs, obtain
fresh air immediately. Turn off the gas sup-
ply to the appliance and have it serviced by
a qualified professional, as it may not be
operating correctly.
FIREBOX FINISHES
There are a wide variety of "finished looks" for
your outdoor fireplace, from formal wall decor
with elaborate mantels to rustic wood paneling
or warm brick facings.
6" Minimum
For Combustible
Materials
See Note
Pilot
Hood
3-3/4" Max.
Note: The Area Above The Face To The Top Of The Spacers
Must Be Non-Combustable Materials
Figure 18 - Clearances To Combustibles
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Only noncombustible materials like marble,
stone, tile, brick, etc. may overlap the top
and sides of the front facing. Seal all joints
between the black facing and wall surrounds
to prevent air intrusion. Use noncombustible
caulking materials only to seal the metal facing
to the surround material on the finished wall.
See Figure 18.
CAUTION: DO NOT BLOCK THE FACE OPEN-
ING ON THESE FIREBOXES. DOING SO MAY
CREATE A POTENTIAL FIRE HAZARD.
5"
Min.
12" Max.
29" Min.
Wall
Switch
13