Fitting Supply Flow Sensor To Electric Shower
The electric shower has one supply line – cold water – fit one flow sensor to this line.
Install the filter which is a Y-Pattern strainer, in the correct position to the shower water supply
line and then fit the flow sensor between the filter and the shower heater.
CHECK: Direction of flow arrow moulded on casing is in the correct orientation.
Connect the sensor cables from the flow sensor to the pump (see electrical installation).
Ensure sensors and strainers are accessible for service and maintenance purposes.
Vertical Cold Water Feed
Fit Flow Sensors between the
strainer and shower.
Allow enough distance so that the
sensors are easily
Flow
Direction
Confirm shower water supply pipework is
flushed before connecting to the shower
sensor via the strainer.
Any building debris in the water supply to the shower
heater will adversely affect the sensor function and
may also damage the shower heater.
Horizontal Cold Water Feed
FILTER IN WRONG POSITION
Flow
Direction
All cable connections must be in a dry location. DO NOT tile over Flow Sensors.
Failure to install the Strainer may invalidate any warranty for the product.
Fit sensor using an approved liquid based thread sealant suitable for nylon threads.
CORRECT
POSITION
accessible.
Sensor
Direction
JG Push-Fit
Strainer
CORRECT POSITION
Direction
Strainer
Sensor Cable
Sensor Tail
Flow
Direction
CHECK FLOW SENSOR DIRECTION
DO NOT tile over Flow Sensors
They must be accessible for servicing
Shower
Sensor Cable
Flow Sensor
Check Flow Direction
10
Flow
WRONG POSITION
CHECK FILTER POSITION
Flow
Flow Sensor
Shower