Dor-O-Matic 96000 Series Kurulum Talimatları Kılavuzu - Sayfa 5

Kontrolör Dor-O-Matic 96000 Series için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Dor-O-Matic 96000 Series 7 sayfaları. Slide control

Setting
Opening speed
Auto-reverse opening
Backcheck position
Backcheck speed
Hold Open Delay
Closing speed
Auto-reverse closing
Latch position
Latch speed
Energy-wise
Electric Lock
Sizing speed
Function
Status Announcement
Reset Power:
If main power needs to be reset for any reason, power must remain off for a minimum of ten (10) seconds to allow proper discharge of internal
circuitry.
84657-084 REV. B
Setting
Value
Factory
Display
Ranges
Default
Settings
OS
1 to 99
85
AO
1 to 99
75
bP
1 to 32
08
bS
50 to 99
80
hd
1 to 32
01
CS
1 to 99
75
AC
1 to 99
50
LP
1 to 32
07
LS
50 to 99
85
EP
50 to 75
50
EL
ON or
OF
OF
SS
50 to 99
85
Fn
00
00
SA
00
00
July 2003
Description
Controls the opening speed of the door. It is recommended that
the door be operated as slowly as practical for the traffic
conditions.
Controls the amount of force required to reverse the door when
opening (see FEATURES).
Controls where backcheck position starts.
Controls the door speed during backcheck.
Controls the amount of time the door stays open. If a presence
sensor is not installed, the time delay must be at least 4 seconds.
Controls the closing speed of the door. It must not exceed 1
ft/sec.
Controls the amount of force required to reverse the door when
closing (see FEATURES).
Controls where latch position starts. It must be at least 2 inches
from the fully closed position.
Controls the door speed during latch.
Adjusts the open position of the door from 50% to 75% of full
open when energy-wise switch is set to narrow.
Enables (ON) or disables (OF) the electric lock delay. If EL is set
to OF, the door opens immediately upon reception of the
activation signal. If EL is set to ON, when the door is fully closed,
there is a 1 second delay between reception of the activation
signal and the actual opening of the door. This delay allows most
electric or magnetic locks time to unlock before the door opens.
Controls the speed of door during sizing.
This setting not used at this time.
This setting not used at this time.
Page 5 of 7