Akw Onyx Exclusif Kurulum Talimatları Kılavuzu - Sayfa 6
Banyo Armatürleri Akw Onyx Exclusif için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Akw Onyx Exclusif 8 sayfaları. Shower tray
solid Floor Installation
position the tray over the desired
location for the shower and outlet
pipe. mark around the edge of the
shower tray and the waste area.
For 'in' floor or 'on' floor installation
remove the floor material for the
waste area and a channel
for the outlet pipe.
lower the tray into position and
check the height compared to the
finished floor height. Firmly secure
the tray into position and check all
4 sides are level again.
6
For 'in' floor installation, cut into
the flooring, taking care not to cut
through any supporting material,
plumbing or electrical wiring.
Install the waste drain trap and
waste outlet pipe. Water test the
waste for flow and for any leaks.
ensure that the rubber seal is in
place on top of the trap. Check the
waste drain position with the tray.
attach the waste trap to the tray
with the waste clamping ring, see
separate waste instructions.
apply a waterproof membrane to
the whole of the showering area,
see manufacturers instructions.
Carefully remove the flooring to
suit the finished height of the
tray and final floor covering. For
'on' floor installation, remove the
material around the waste area.
remove any debris and ensure
that there are no sharp edges or
raised areas that will affect the tray
height. Add 6:1 cement mix to the
full tray area and correct height
including all supporting edges.
Safety flooring or tiles should
finish flush up to the edges of
the tray and sealed with sealant.
protect the waste trap and cover
from debris during installation.
General: 01905 823 298
|
www.akw-ltd.co.uk