Clear Accumulator and Counter
Press the ACCUM button to enter the accumulator and counter recall mode. The display
will show Accunn followed by the accumulated weight in the units currently selected in
the weigh mode. Then Countr will be displayed followed by the counter value.
Press CLEAR to clear the accumulator and counter values. The display will show
Clr Ac and exit from the recall mode.
Changing the current display units will clear both the accumulator and counter values.
Accumulator and Counter Data String Output to Printer or Other Device
Press ACCUM to enter the accumulator recall mode. Press PRINT to transmit the LB4
custom data string that contains the accumulator and counter values by default. Both
the accumulator and counter values are cleared after transmission.
See Output Formats in the parameter section and Custom Data String default settings
for more details.
Accumulator and Counter Operation
When a manual or automatic print function is executed, the accumulator has the
currently displayed weight added to its' current value and the counter is incremented.
To confirm an accumulation and counter operation, the left most display digit will
momentarily display an o.
To automatically accumulate, select an auto print function in the parameter setup menu.
To accumulate manually, allow the scale to become stable and press PRINT.
The maximum value that can be shown for the accumulator and counter is 999,999.
When the maximum value is reached, the accumulator or counter will rollover to a zero
value. The accumulator and counter feature can only be used in a non Legal For Trade
application.
Display ID Values
Press ID to enter the ID recall mode. The last viewed or edited ID will be displayed.
The display will show Id, followed by the current ID's value. Press UNITS and PRINT to
scroll through the eight available IDs. The annunciators below the main display indicate
the current setpoint. Press ID to exit this mode, the display will read abort to indicate
no changes were made to the setpoint values.
The ID displayed is the last edited or displayed ID.
13