Doran Scales DS100 Operatör El Kitabı - Sayfa 10

Ölçüm Cihazları Doran Scales DS100 için çevrimiçi göz atın veya pdf Operatör El Kitabı indirin. Doran Scales DS100 15 sayfaları. Scale indicator

"Gn" Example (Negative weight, in motion)
25.15 lb GR MOT.♪
20.05 lb NT MOT.♪
5.10 lb TR MOT.♪
"Gn" Print String Definition for Each Weight Unit:
Pounds
STX | POL | WEIGHTGROSS | SP | lb | SP | GR | SP | ST | CR | LF
STX | POL | WEIGHTNET | SP | lb | SP | NT | SP | ST | CR | LF
STX | POL | WEIGHTTARE | SP | lb | SP | TR | SP | ST | CR | LF
Ounces
STX | POL | WEIGHTGROSS | SP | oz | SP | GR | SP | ST | CR | LF
STX | POL | WEIGHTNET | SP | oz | SP | NT | SP | ST | CR | LF
STX | POL | WEIGHTTARE | SP | oz | SP | TR | SP | ST | CR | LF
Kiligrams
STX | POL | WEIGHTGROSS | SP | kg | SP | GR | SP | ST | CR | LF
STX | POL | WEIGHTNET | SP | kg | SP | NT | SP | ST | CR | LF
STX | POL | WEIGHTTARE | SP | kg | SP | TR | SP | ST | CR | LF
Grams
STX | POL | WEIGHTGROSS | SP | g | SP | GR | SP | ST | CR | LF
STX | POL | WEIGHTNET | SP | g | SP | NT | SP | ST | CR | LF
STX | POL | WEIGHTTARE | SP | g | SP | TR | SP | ST | CR | LF
Pounds-ounces
STX | POL | WEIGHTLBGROSS | SP | lb | POL | WEIGHTOZGROSS | SP | oz | SP | GR | SP | ST | CR | LF
STX | POL | WEIGHTLBNET | SP | lb | POL | WEIGHTOZNET | SP | oz | SP | NT | SP | ST | CR | LF
STX | POL | WEIGHTLBTARE | SP | lb | POL | WEIGHTOZTARE | SP | oz | SP | TR | SP | ST | CR | LF
STX (
POL = minus sign for negative weight or a space for a positive weight
WEIGHT[GROSS/NET/TARE] = 6 character field plus decimal if needed
WEIGHTLB[GROSS/NET/TARE] = pound portion of lb-oz weight
WEIGHTOZ[GROSS/NET/TARE] = ounce portion of lb-oz weight. (WEIGHTLB and
SP = ASCII space
ST = MOT. if in motion or a space if stable
CR (
) = Carriage return
LF (
) = Linefeed
| = Separator, not printed

Remote Scale Commands

The scale will respond to the following single letter ASCII commands.
"W"
"U"
"Z"
) = ASCII 02
WEIGHTOZ total 5 characters plus decimal)
Initiates transmission of current weight data (if in motion, scale will
wait until stable, then print).
Changes the displayed weight units.
Zeroes the scale (if in motion, scale will wait until stable, then zero).
8