ELECTRICAL
Please ensure that the required voltage of the compressor is being supplied at
all times. Low or high voltage can detrimentally affect the refrigeration unit
All units should be plugged into a grounded and properly-sized electrical outlet
with
appropriate
overcurrent
protection.
Please
refer
to
the
electrical
requirements on the nameplate of the unit. Please make sure that your unit has
its own dedicated outlet. Do not use an extension cord.

TEMPERATURE CONTROLS

The temperature controls are factory-set to maintain an average temperature of
38 F in refrigerators and 0 F in freezers. To maintain a different temperature,
simply adjust the control knob located inside the unit.
To decrease the temperature (colder), turn clockwise. To increase the
temperature (warmer), turn counter-clockwise
CAUTlON
Setting the temperature control to the coldest setting may cause the evaporator
coil to freeze and ice up. This will eventually result in a warmer cabinet
temperature.

LOADING PRODUCT

Shelves have been factory-installed for your convenience. Before loading
shelves, please be sure that all shelf clips are completely fastened in their
correct locations. It is important that all shelves rest completely level before
stocking your cabinet with product.
In order to maintain correct air flow inside the unit, please be sure to leave two
to four (2 to 4) inches of space between the back wall and stored product.
Blocking the evaporator fans will result in a warmer cabinet temperature, and
ultimately compressor failure.

DEFROST SYSTEMS

Refrigerator coils are kept below the freezing point (32 F). During compressor
down-time, the evaporator fan continues to circulate air through the evaporator
coil. This air circulation raises the coil temperature above the freezing point,
melting any accumulated frost. Run-off water is drained into the evaporator pan
and evaporated. Freezer coils are defrosted electrically. Automatic defrost
timers are built-in to the refrigeration system and may not be adjusted. The
defrost timers automatically initiate at pre-set intervals and for a pre-determined
duration.