Dorlen Water Alert SS-1 Talimatlar - Sayfa 2

Güvenlik Sensörleri Dorlen Water Alert SS-1 için çevrimiçi göz atın veya pdf Talimatlar indirin. Dorlen Water Alert SS-1 2 sayfaları.

SETUP AND ADJUSTMENTS
1.
To adjust sensor height, hold straight edge across
pads (B1 & B2). Turn sensors (A & A) out or until
distance to straight edge equals the desired water
detection level. See Figure 2.
2.
Connect battery leads (E) and (E') to terminals of
batteries (C) and (C'). Then insert the batteries into
retainer clips. Then connect red wire(+) and black
wire(-) from remote alarm enclosure to + and - of
water alert with wire nuts supplied.
3.
Wait ten seconds, then test unit by touching wet
fingers to both sensors(A-A). The unit should ac-
tivate.
4.
Fasten remote alarm enclosure in desired location
using screws and inserts supplied, 1/4" holes required
(F-F-F-F). Position Water Alert in desired location
and retest it by placing wet fingers across the heads
of the two screws on which sensors are mounted
The unit should activate.
5.
When activated, the unit will be in alert condition
for 2-3 seconds and turn off for 5-7 seconds to
conserve battery resources. To silence enclosure,
use locking silence switch ( pull switch handle, then
transfer down).
6.
To reset the unit, simply remove it from water. If
necessary, dry off the sensor area if it is excessively
wet (if the unit was submerged).
NOTE
Do Not Use Batteries
Other Than Alkaline!
FIGURE 2
BOTTOM VIEW
MADE IN USA
Model
B3
C
SS-1
WATER ALERT
E
A
B1
SS-1
INSTRUCTIONS
BATTERIES
1.
Two 9-volt alkaline batteries (NEDA size 1604A) are
required. Approximate alarm duration time (after one
year monitoring) is 1.5 days.
2.
The Alkaline batteries should be replaced once a year.
If the unit is activated often, the batteries might need
to be replaced sooner.
3.
Whenever the batteries are replaced, it is a good
practice to wipe clean the top surface of the Water
Alert and its sensors.
4.
A Dorlen Power Supply, such as the PS-3, may be
used in place of batteries. If so, follow the furnished
instructions for wiring.
Not For Explosive Environments!
C
Red
Black
E
A
B2
CAUTION
F
F
REMOTE ALARM ENCLOSURE
10mm LED
Light
2 conductor wire
#22 AWG. - 50'
Audible Alarm
Wire Nuts
F
F
Silence
F
5-12
M-9938