Canon LV-7555 Teknik Özellikler
MR3P
Series Basic Serial Command Function Specification
‚ T .8
Status Read Command
Command
"CR0" [CR]
Detail
Get the projector status
Acceptable
Response
Unacceptable
• y Details for Response • z
‚ T .8.1
"00" [CR]
POWER ON
Normal screen is displayed.
‚ T .8.2
"80" [CR]
STAND BY
When the status is STAND BY, Status Read Commands are always
acceptable, but Functional Execution Commands are not acceptable except
Power ON Command.
‚ T .8.3
"40" [CR]
Processing Count Down
When "Display" in Setting Menu is ON and Power ON is executed, it starts
processing Count Down. Also, when "Display" OFF in the setting menu is
set, processing Count Down is skipped and the status moves to Power ON
quickly.
‚ T .8.4
"20" [CR]
Status: Cooling
When status is Power ON, and Power OFF Command is executed, it moves
to cooling status. This cooling status automatically moves on to Standby
after the lamp turns off and the fan spin for about 90seconds.
The time defers from models. This Cooling Down Works for lamps and other
optical accessories. Control commands are not available for this status.
"%1" [CR]
"00" = POWER ON
"80" = STANDBY
"40" = Processing Count Dow
"20" = Processing Cooling Down
"10" = Power Failure
"28" = Processing cooling down due to abnormal temperature
"08" = Abnormal Temperature
%1
"88" = normal after recovering abnormal temperature
"24" = Processing Power Save• E Cooling Down
"04" = Power Save
"21" = Processing cooling down after turning off automatically
due to a lamp failure
"81"= Standby after cooling down due to a lamp failure
"• H " [CR]
Soft Engineer Division
Page
21 / 24