Dorma ESA II Hızlı Başlangıç Kılavuzu
Kontrolör Dorma ESA II için çevrimiçi göz atın veya pdf Hızlı Başlangıç Kılavuzu indirin. Dorma ESA II 2 sayfaları.
Ayrıca Dorma ESA II için: Manuel (10 sayfalar)
DORMA
1 Door must be installed and adjusted completely. The door must slide without binding.
2 Door must be fully wired and safety devices must be normally closed
If using BEA Wizards change presence to NC output by changing the relay output from the default of 4 to 1 with
the remote.
If using the Reglomat Profusion change presence output to NC with remote by pressing E +2+2
If the door has Micro Cell holding beams wired to one presence input wire the Wizards as follows to the one open
presence input. Wire nut the blue from one Wizard to the brown of the other then wire the remaining blue and
brown to the presence input. (The Wizards have to be wired in series if connected to one input.)
The door will not tune in or function without a closed contacts or jumpers on the following terminals 21 (Dish)
and 23 (Arrow) Presence 2, 26 (Dish) and 28 (Arrow) Presence 1 and terminals 32 and 33 Breakout (Emergency
Stop)
3 With the power disconnected slide the door open half way. Place the jamb switch to the off or closed position, Exit
only off and Partial Open to off.
4 Plug the power in and observe the door after a few seconds the door should move in the closing direction if it
opens unplug the power and see step 5 if it closes move to step 6.
5 If at initial startup the door moved in the opening direction with the power disconnected slide the door open half
way then press and hold the Service button. While pressing the Service button connect the power plug. Hold the
button until you see and 8 appear in the display. The 8 will flash twice once the reset is complete.
If the door moves in the closing direction proceed to 6. If it moves in the opening direction press the minus (-)
button to change the motors direction.
6 After the door closes perform a learn cycle by pushing the Service button until the display starts to rotate. The
door accelerates to determine the door weight and then open the rest of the way in creep speed.
The 8 will blink twice then a dot will appear indicating that the learn cycle is complete and the door will close at
normal speed.
DORMA AUTOMATICS, Inc.
ESAII CONTROLER
Quick Start
Quick Start Guide ESAII
924 Sherwood Drive
Lake Bluff, IL 60044
E-mail: [email protected]
DL0000-000
Toll-Free: 877-367-6211
8/25/2009
Fax: 877-423-7999
Subject to change without notice
NC Safety Circuit
Presence output
NC input or Jumpers on
21 & 23, 26 & 28, and 32
& 33
Switch in Off position
for Tune in.
Door should close at start
up
Perform a learn cycle.
1 of 2