dormakaba MUTO Premium XL150/80/120 / MUTO Comfort L80
Fixed Panel Installation Instructions
2.3
Secure sidelite section profile to track and mounting surface
Fig. 2 MUTO ceiling mount track
Track
Sidelite
section
profile
2.3.1 Align sidelite profile screw slot with track profile
holes.
NOTE: Holes will be predrilled every 7-7/8" [200].
2.3.2 Secure with provided fasteners.
NOTE:
OVERHEAD REINFORCEMENT:
The overhead reinforcement must be a minimum of ¼"
[6] x 3" [76] steel angle, 16 gauge metal stud, or two
pieces of 1 1/2" [38] thick wood blocking (double
stacked), secured to studs or joists on a maximum 16"
[406] centers for the length of the track. The overhead
reinforcement may be flush on the overhead surface or
on the interior of this surface.
MUTO Premium/Comfort Fixed Panel
2.3.3 Ensure track is properly level and secure it to the
NOTE: SEE DIMENSION INSTRUCTIONS ON NEXT
PAGE FOR REFERENCE.
2.3.4 Use appropriate fasteners according to the
Track mounting screws must fully penetrate the steel
angle, metal stud, or at a minimum of 2" [51] into wood
blocking, utilizing the predrilled holes in the MUTO
track.
Consult with a structural engineer to determine if
reinforcement is adequate for your specific application
or to meet specific codes in your location.
936020
header mounting surface per the appropriate
measurements on the following page.
following recommendations.
Track
05-2018
7