H1000 EX1000 COMMUNICATION
H1000 to MAP2 Communication LEDs
The EX100 RS485 of the H1000 communication is indicated by RX485 - LED1 and
TX485 - LED2. The green TX RS485 LED will only toggle when the address of the
Auxiliary H1000 is sent from the MAP2 elevator control panel. When the auxiliary H1000
receives this poll it will send the response to the MAP2 elevator control panel. See previous
section which describes the "MAP2 PLM Communication"
RX485 LED
H1000 RD8, RD7, RD6 LEDs
RLED7
RLED8
An additional auxiliary H1000 panel setup verification is implemented in this firmware.
Three LEDs are used to indicate what address the auxiliary H1000 panel is set to. These
LEDs near the reader ports RD8, RD7 and RD6 are labeled as RLED8, RLED7 and
RLED6 respectively. Each time the MAP2 elevator control panel communicates to the
auxiliary H1000 panel, one of these LEDs will toggle. If the auxiliary panels have been
correctly configured, the correct LED that will toggle is indicated below:
Auxiliary 1 = RLED8
Auxiliary 2 = RLED7
Auxiliary 3 = RLED6