Bolton Tools HP-L4G Kurulum, Çalıştırma ve Bakım Kılavuzu - Sayfa 7

Kaldırma Sistemleri Bolton Tools HP-L4G için çevrimiçi göz atın veya pdf Kurulum, Çalıştırma ve Bakım Kılavuzu indirin. Bolton Tools HP-L4G 16 sayfaları. Two-post model autolift

The chalk line layout is very important. If it is not followed accurately problems may arise in final
assembly and operation.
5. Using a lifting device, Erect both column assemblies with the installation lines.
A
NCHORING
6. The anchor bolts must be installed at least 8 inches from any crack, edge, or expansion joint.
7. Use a concrete hammer drill with a 5/8 inch carbide bit. Do not use excessively worn bits or bits
which have been incorrectly sharpened. A core bit may be necessary if an obstruction is encountered.
Never substitute with shorter anchor.
8. Vacuum dust from the hole for proper holding power.
9. Shim both columns to plumb using the shims provided. DO NOT shim more than 1/2" at any given
point. Use a level no less than 24" in length to plumb columns.
10. Assemble washer and nut to anchor with nut just below impact section of bolt. Drive anchor into
hole until nut and washer contact base.
11. Tighten power column anchors and recheck column for plumb. Reshim if necessary. Torque to 150
foot pounds to set anchors.
floor-plate ass'y
12. Assemble
S
YNCHRONIZER CABLES
13. Manually raise the carriages until each is located on the second lock position.
14. Route synchronizing cables using Fig 4 and attach ends to carriages' joining using Fig's 5.
15. Adjust cable tension by adjusting each cable's adjustment nuts. The cables should be tight with no
slack. Each cable should be the same tension. Be sure as you are tightening the cables that they have
remained in place over the pulleys. Failure to do this will result in damage to the cable.
Fig 3
Be sure to stay within a 1/4 inch overall tolerance. This will eliminate any
difficulty in final assembly or possible premature chain wear or
misalignment.
Never remove the lift before the columns Tightened by the anchor bolts.
F
LOOR-PLATE
to floor.
5