Port
Port Name
ALARM_OUT
ALARM_OUT_GN
D
Alarm I/O
ALARM_IN
ALARM_IN_GND
1.2

Connecting Alarm Input/output

Alarm input/output is available on select models.
Step 1
Connect alarm input device to the alarm input end of the I/O port, see Figure 1-2.
Device collects different states of alarm input port when the input signal is idling and being
grounded.
Device collects logic "1" when input signal is connecting to +3V to +5V or idling.
Device collects logic "0" when input signal is grounded.
Step 2
Connect alarm output device to the alarm output end of the I/O port. The alarm output is
open-drain output, which works in the following modes.
Mode A: Level application. Alarm outputs high and low level, and the alarm outlet is OD,
which requires external pull-up resistance (10K Ohm typical) to work. The maximum
external pull-up level is 12V, maximum port current is 300mA and the default output
signal is high level (external pull-up voltage). The default output signal switches to low
level when there is alarm output (As long as the operating current below 300mA, the
output low level voltage is lower than 0.8V).
Mode B: Switch application. Alarm output is used to drive external circuit, the
maximum voltage is 12V and the maximum current is 300mA. If the voltage is higher
than 12V, please use an additional electric relay.
Table 1-2 Alarm information
Function
Outputs alarm signal to alarm device.
When connecting to alarm device, only the ALARM_OUT port and
ALARM_OUT_GND port with the same number can be used
together.
Receives the switch signal of external alarm source.
Connect
different
ALARM_IN_GND port.
Figure 1-2
2
alarm
input
devices
Alarm input
Quick Start Guide
to
the
same