Dahua H Hızlı Başlangıç Kılavuzu - Sayfa 9

Güvenlik Kamerası Dahua H için çevrimiçi göz atın veya pdf Hızlı Başlangıç Kılavuzu indirin. Dahua H 20 sayfaları. Ir dome network camera

Dahua H Hızlı Başlangıç Kılavuzu
Port
Alarm I/O
1.2

Connecting Alarm Input/Output

Alarm input/output is available on select models.
Step 1
Connect alarm input device to the alarm input end of the I/O port. See Figure 1-2.
Device collects different states of alarm input port when the input signal is idling and
grounded.
Device collects logic "1" when input signal is connecting to +3V to +5V or idling.
Device collects logic "0" when input signal is grounded.
Step 2
Connect alarm output device to the alarm output end of the I/O port. The alarm output
is relay switch output, which can only connect to NO alarm devices.
The ALARM_OUT port and the ALARM_OUT_GND port with the same number
constitute a switch for alarm output. See Figure 1-3. The switch is open normally and
closes when there is alarm output.
Table 1-2 Alarm I/O port introduction
Port Name
ALARM_IN (pin1–
pin3)
GND (pin4)
ALARM_NO1 (pin5)
ALARM_NO2 (pin7)
ALARM_COM1 (pin6)
ALARM_COM2 (pin8)
Description
Receives the switch signal of external alarm
source.
Connect all the alarm input devices to the same
GND port.
Outputs alarm signal to alarm output device.
When connecting to alarm output device, only the
ALARM_NO port and ALARM_COM port with the
same number can be used together.
Figure 1-2
Alarm input
Introduction 2