Address
Parameter
applying bitwise mask defined in
0x07E39D)
0x07E395
Delay between detection of master
address claim and starting RUN
mode
0x07E396
Delay between detection of master
address claim and first PDU1
transmission
0x07E398
Lowest device address to claim in
address resolution sequence
0x07E399
Highest device address to claim in
address resolution sequence
0x07E39A
CAN Bus speed.
0 = 250k
1 = 500k
2 = reserved (do not use)
0x07EF40
Reset device to default values
Write data in this sequence to
reset all non-volatile SPNs to
default values: 0x00, 0xAA, 0x55,
0x12, 0x34
(4) Detection range can be adjusted to avoid issues with double echo detections.
(5) SPN value is reset to default after a power cycle (volatile)
(6) Accuracy reduced
Page 24 of 32
range
offset
scaling
0..5000
0
1ms
0..5000
0
1ms
128..209
0
1
128..209
0
1
0..1
0
1
N/A
N/A
N/A
R600V.DAH5_manual_1.5 (EN).docm
Default value
250
200
128
209
0
N/A