Baumer HOGS 100 S Kurulum ve Kullanım Talimatları Kılavuzu - Sayfa 5

Medya Dönüştürücü Baumer HOGS 100 S için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Talimatları Kılavuzu indirin. Baumer HOGS 100 S 36 sayfaları. Sine encoder with function safety
Ayrıca Baumer HOGS 100 S için: Kurulum ve Kullanım Talimatları Kılavuzu (32 sayfalar)

1

General notes

1.1
Symbol guide:
Danger
Warnings of possible danger
General information for attention
Informations to ensure correct product operation
i
Information
Recommendation for product handling
1.2
The sine encoder HOGS 100 S is an opto electro nic precision measurement device which
must be handled with care by skilled personnel only.
1.3
The expected operating life of the device depends on the ball bearings, which are equipped with
a permanent lubrication.
1.4
The sine part of the HOGS 100 S can be employed in function safety drive systems.
An error condition of the encoder is visible in the output signal until 25 ms.
The subsequent electronics have to detect that the signal amplitude is out of the interval
[0.7 V..1.4 V
pp
Please follow "Subsequent electronics requirements" in section 7.4.
There is no prevention by the encoder that the system get in operation after an error
occures. If it is required to stop the system continuously it must be guaranteed via the
subsequent electronics.
1.5
The storage temperature range of the device is between -15 °C and +70 °C.
1.6
The operating temperature range of the device is between -20 °C and +85 °C,
restricted in potentially explosive environments, see section 2, measured at the housing.
1.7
EU Declaration of Conformity meeting to the European Directives.
1.8
The device is UL approved (not applicable for operation in potentially explosive atmospheres).
1.9
We grant a 2-year warranty in accordance with the regulations of the ZVEI (Central Association
of the German Electrical Industry).
1.10
Maintenance work is not necessary. Repair work must be carried out by the manufacturer. Al-
terations of the device are not permitted.
1.11
In the event of queries or subsequent deliveries, the data on the device type label must be
quoted, especially the type designation and the serial number.
1.12
Encoder components are to be disposed of according to the regulations prevailing in the re-
spective country.
i
Warning!
Damaging the seal
MB183b - 11076867
] or the phase shift is out of the interval [90°±45°].
on the device invalidates warranty.
Baumer_HOGS100S_II_DE-EN (16A3)
1
General notes
2