Baumer Hubner Berlin CANopen PMG 10 Kurulum ve Kullanım Talimatları Kılavuzu - Sayfa 12

Medya Dönüştürücü Baumer Hubner Berlin CANopen PMG 10 için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Talimatları Kılavuzu indirin. Baumer Hubner Berlin CANopen PMG 10 28 sayfaları. Absolute encoder with magnetic sensing

MOUNTING
4.4
Maximum permissible mounting tolerance when the Baumer Hübner K 35 spring
disk coupling is used
Encoders should be driven through the Baumer Hübner K 35 spring disk coupling (acces-
)
sory), that can be pushed onto the shaft without axial loading�
The encoder must be mounted on the drive with the least possible angular error
)
and parallel misalignment�
Risk of damaging the ball bearings
Coupling components must not be driven onto the shaft with improper force (e� g�
hammer impacts), because of the risk of damaging the ball bearings�
Admissible
parallel misalignment
* For insulated hub version
All dimensions in millimeters, unless otherwise stated�
9/25
2-10
Admissible
angular error
MB251EN - 11173962, 16A1, Baumer_PMG10-CANopen_II_EN
Admissible
axial movement
±0�7 (±0�3*)