Baumer HUBNER BERLIN DeviceNet PMG 10 Kurulum ve Kullanım Talimatları Kılavuzu - Sayfa 25

Medya Dönüştürücü Baumer HUBNER BERLIN DeviceNet PMG 10 için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Talimatları Kılavuzu indirin. Baumer HUBNER BERLIN DeviceNet PMG 10 28 sayfaları. Absolute encoder with magnetic sensing

8.

TECHNICAL DATA

8.1
Technical data - electrical ratings
Voltage supply
Short-circuit proof
Consumption w/o load
Initializing time
Interface
Function
Transmission rate
Device adress
Steps per turn
Number of turns
Additional outputs
Sensing method
Interference immunity
Emitted interference
Programmable parameters
Diagnostic function
Status indicator
Approvals
8.2
Technical data - electrical ratings (speed switches)
Interface
Switching accuracy
Switching outputs
Output switching capacity
Switching delay time
* Depending on version
MB253EN - 11173971, 16A1, Baumer_PMG10-DeviceNet_II_EN
10���30 VDC
yes
≤200 mA
≤500 ms after power on
DeviceNet
Multiturn
125���500 kBaud
Rotary switches in
bus connecting box (type-speciic)
8192 / 13 bit
65536 / 16 bit
Square-wave HTL
Square-wave TTL (RS422)
Magnetic
EN 61000-6-2
EN 61000-6-3
Steps per revolution
Number of revolutions
Preset, scaling, rotating direction
Position or parameter error
DUO-LED in bus connecting box
4 LEDs in device back side
CE
RS485
±2 % (or Digit)
1 output
(Open-Collector* or Solid State Relay*)
30 VDC; ≤100 mA
≤20 ms
TECHNICAL DATA
22/25