Baumer Hubner Berlin microGen PMG10 Kullanım Kılavuzu - Sayfa 17

Medya Dönüştürücü Baumer Hubner Berlin microGen PMG10 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Baumer Hubner Berlin microGen PMG10 40 sayfaları. Absolute encoder
Ayrıca Baumer Hubner Berlin microGen PMG10 için: Kullanım Kılavuzu (44 sayfalar), Kullanım Kılavuzu (40 sayfalar)

Baumer Hübner
g) Fasten the coupling onto the shaft of the drive at a torque of 1.3 ±10 % Nm.
Observe the remarks in the data sheet and the coupling assembly instructions.
Maximum permitted tolerances for mounting errors when using the
5.3
Baumer Hübner K 35 spring washer
NOTICE
Damage to the encoder ball bearings.
Hard impacts of the drive shaft imposed on coupling parts may damage the ball bearings.
a) Prevent any hard impacts of the drive shaft on coupling parts.
Instruction:
a) Mount the drive with small angular error and parallel offset.
b) Note the following allowable mounting errors:
The figure shows the device with EURO flange B10, the same maximum permissible mounting
errors must be observed for the device with housing foot B3.
Permitted parallel misalignment
* With insulated plastic hub
Ill. 7: Permissible mounting errors (dimensions in mm)
V1 | PMG10 & PMG10P Profibus DP
Permitted angle error
Operating Manual
Installation
Permissible axial movement
±0.7 (±0.3*)
|
5
17