Baumer Hubner Berlin microGen PMG10 EtherCAT Kullanım Kılavuzu - Sayfa 16

Medya Dönüştürücü Baumer Hubner Berlin microGen PMG10 EtherCAT için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Baumer Hubner Berlin microGen PMG10 EtherCAT 36 sayfaları. Absolute encoder

5
|
Installation
1
Ill. 6: Mounting encoder onto drive shaft
1
Drive shaft
3
M6x20 mm screw for fastening the hous-
ing base (ISO 4017)
5
Housing foot (according to product vari-
ant)
Tools
2.5 mm
n
n
Instruction:
a) Prior to installation, check the drive runout error and dimensions.
b) Mount the encoder in a way ensuring the electrical connection is protected against direct
water ingress.
c) Apply grease onto the drive shaft.
d) Push the encoder coupling onto the shaft of the drive.
e) In doing so, align encoder and drive shaft to minimize parallel offset and angular errors.
f) Mount the encoder to the base using the screws (4x) and washers (4x).
16
5
10 mm
Operating Manual
2
90 mm
2
Coupling
4
Washer B6 for fastening the housing
base (DIN 137)
PMG10 & PMG10P EtherCAT | V1
Baumer Hübner
3
4
5