Baumer Hubner PMG10 Montaj ve Kullanım Talimatları - Sayfa 17
Medya Dönüştürücü Baumer Hubner PMG10 için çevrimiçi göz atın veya pdf Montaj ve Kullanım Talimatları indirin. Baumer Hubner PMG10 36 sayfaları. Absolute encoder ssi with magnetic sensing
5.2
SSI interface
5.2.1
Data transfer
Clock
Data
Clock frequency 100 kHz���2 MHz
Monoflop time (t) 20 µs (internal)
n, m Number of bits
i
For continous clocking, the SSI word is transmitted only once followed by zero
values (no ring register operation)�
5.2.2
Function „RESET"
With the function „RESET" (RESET input) the position value of the SSI signal is set to
0 (factory setting, other values are possible on request)�
» A voltage of 4���30 VDC must be applied to the RESET input for more than 100
ms to set the current position to 0�
i
The RESET input has no influence on the incremental signals.
The RESET input has no influence on the speed switch.
i
If a voltage of 4���30 VDC is applied to the RESET input during the initialization
phase after switching on, the delay time of 100 ms does not begin until after the
initialization phase�
5.2.3
Function „Rotating direction"
The function „rotating direction" (DIR input) reverses the rotating direction of the SSI
signal�
» A voltage of 4���30 VDC must be applied to the DIR input for more than 100 ms
to reverse the current rotating direction of the SSI signal� For the duration of
the applied voltage of 4���30 VDC, the rotating direction of the SSI signal is then
reversed�
i
The DIR input has no influence on the incremental signals.
The DIR input has no influence on the speed switch.
MB245EN - 11171693, 19A3, Baumer_PMG10-SSI_II_EN
Position
Speed
n-1...0 bit m-1...0 bit
msb → lsb msb → lsb
ELECTRICAL CONNECTION / SSI INTERFACE
t
14/29