8.4
Technical data - mechanical design
• Sensor head:
• Size (flange):
• Shaft type:
• Axial tolerance:
• Radial tolerance:
• Protection DIN EN 60529:
• Operating temperature:
• Operating speed:
• Materials:
• Resistance:
• Accuracy of magnetic measure:
• Connection:
MB211T1 - 11105827
Baumer_MHGP200-T1_II_DE-EN (19A2)
FPGA signal processing
ø201.7 mm
ø50...180 mm (through hollow shaft)
(as ordered)
±3 mm (wheel/head)
0.1...2.2 mm (wheel/head)
IP67 (head)
IP68 (wheel)
-20...+85 °C
≤4000 rpm
Housing sensing head: aluminium alloy
Wheel: stainless steel (1.4104)
IEC 60068-2-6
Vibration 30 g, 55-2000 Hz
IEC 60068-2-27
Shock 300 g, 2 ms
±150 "
Flange connector M23, 12-pin
Montage / Mounting
4 8
24